Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. bras. queimaduras ; 14(4): 257-262, Out-Dez.2015. ilusuras, 4, ilusuras
Article in Spanish | LILACS | ID: lil-793075

ABSTRACT

Describir la aplicación de presoterapia, en quemaduras faciales en pacientes pediátricos, confeccionando máscaras con vendas autoadherentes, elásticas, finas y permeables durante el tratamiento agudo y post autoinjerto. Método: Estudio descriptivo, longitudinal y prospectivo. Criterios de inclusión: paciente que ingresaron a la Unidad de Quemados del Hospital Profesor Doctor Juan Pedro Garrahan, desde 25/08/2013 hasta 30/06/2015, con quemaduras faciales de cualquier etiología, dentro de los primeros tres días de evolución de la lesión y aquellos que recibieron autoinjerto en la región facial. Para la confección de las máscaras se utilizó venda autoadherente, elástica, fina y permeable de 7,5 y 10 cm de ancho, marca Aurinco®. Resultados: N=27 pacientes. 12 pacientes (44%) de sexo femenino y 15 pacientes (55%) masculino. Mediana de edad 60 meses (rango 2-180). Etiologías: 17 pacientes (63%) fuego, 4 (15%) inflamación de líquidos, 3 (11%) líquidos calientes, 1 (3,7%) semisólidos calientes, 1 (3,7%) fogonazo y 1 (3,7%) vapor de agua. 23 pacientes recibieron tratamiento en la etapa aguda, 4 luego del autoinjerto y 11 pacientes en ambas instancias. Se evidenció disminución paulatina del edema local e integración del 100% de los injertos. Consideraciones: La disminución del edema favoreció la reepitelización. La presoterapia colaboró con la rápida integración del injerto y evitó desplazamientos involuntarios, contribuyendo así a mejores resultados estéticos y funcionales. La aceptación del tratamiento fue generalizada, por parte del paciente y del equipo de salud. Las máscaras facilitaron la fijación externa de los tubos endotraqueales y la colocación de interfases de ventilación no invasiva...


To describe the application of compression bandage therapy, in facial burns of pediatric patients, making masks with elastic, thin and permeable self-adhesive bandages during the acute treatment and inmediately after face grafting. Patients and Methods: A prospective, longitudinal and descriptive study was conducted. Inclusion criteria: all patients who were admitted to the burn unit of Hospital Profesor Doctor Juan Pedro Garrahan with facial burns of any cause within 3 days of evolution and underwent facial grafting between August 25, 2013 and June 30, 2015. The mask was made of a 7.5- and 10-cm thin, elastic, permeable, and self-adherent bandage (Aurinco®). Results: N=27 patients, 26% of all admitted (104 patients) were included; 12 (44%) were female and 15 (55%) male. Median age was 60 months (range, 2-180). Burn causes was fire 17 (63%) patients, flammable liquids 4 (15%), scalds 3 (11%), hot semisolids, flammable gas, and steam 1 (3.7%) each. 23 patients received treatment in the acute stage, 4 after grafting and 11 patients in both instances. In all cases the gradual reduction of local edema was evident to reach a plateau after 5 days of treatment and integration of 100% of graft. Considerations: The reduction of edema promotes the spontaneous re-epithelialization. The immediate compression bandage therapy after grafting collaborates with the fast integration of the graft and avoids involuntary displacement, thus contributing to better aesthetic and functional results. The acceptance of treatment was widespread, by the patient and the health team. The presotherapy masks provide external fixation for endotracheal tubes and placing non-invasive ventilation interfaces...


Descrever a aplicação da presoterapia em queimaduras faciais em pacientes pediátricos. Método: Estudo descritivo, longitudinal e prospectivo. Critérios de inclusão: pacientes que foram internados na Unidade de Queimados do Hospital Professor Doctor Juan Pedro Garrahan, de 25 de agosto de 2013 a 30 de junho de 2015, com queimaduras faciais de qualquer etiologia, dentro dos primeiros três dias de evolução da lesão e aqueles que receberam autoenxerto na região facial. Para a confecção das máscaras se utilizou venda autoaderente, elástica, fina e permeável de 7,5 e 10 cm de largura, marca Aurinco®. Resultados: Participaram 27 pacientes. Doze (44%) do sexo feminino e 15 (55%) masculino. Mediana de idade de 60 meses (variando de 2 a 180). Etiologias: 17 pacientes (63%) queimaduras por fogo direto, 4 (15%) líquidos inflamáveis, 3 (11%) líquidos quentes, 1 (3,7%) substâncias semissólidas quentes, 1 (3,7%) gás inflamável, e 1 (3,7%) por vapor de água. Vinte e três pacientes receberam tratamento na etapa aguda, 4 após o autoenxerto e 11 pacientes em ambas as situações. Se evidenciou diminuição paulatina do edema local e integração de 100% dos enxertos. Considerações: A diminuição do edema favoreceu a reepitelização. A presoterapia colaborou com a rápida integração do enxerto e evitou deslocamentos espontâneos, contribuindo, assim, com melhores resultados estéticos e funcionais. A aceitação do tratamento foi generalizada, por parte do paciente e equipe de saúde. As máscaras facilitaram a fixação externa dos tubos endotraqueais e a colocação de interfases de ventilação não invasiva...


Subject(s)
Humans , Child , Adolescent , Pediatrics , Burns/rehabilitation , Transplantation, Autologous , Physical Therapy Specialty
SELECTION OF CITATIONS
SEARCH DETAIL